Back to Top

Hi, Guest!

  LOKASI :  Cibubur, Jatisampurna

Bergabung Selama :

BAGIKAN :   

Bagikan :

TEMPERATURE SCANNER - MURPHY TDX6

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
52 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail TEMPERATURE SCANNER - MURPHY TDX6

TEMPERATURE SCANNER MODEL : TDX6 BRAND : MURPHY Features : * Scans 6 channels * Adjustable trip points * “ J” or “ K” thermocouples * Powered by CD ignition, 24 VDC, or 120 VAC * Rated for class I, division 2, group D hazardous areas * start-up time delay * easy to read digital display Specifications : * Power Requirements ( Operating Voltages) : 120 VAC or 80-250 VDC, CD ignition or 24 VDC. * Outputs: - Models TDX6-A and TDX6-C: Six ( 6) isolated Silicon Controlled Rectifier ( S.C.R.) outputs; 0.5 A @ 250 VDC; switches on ( applies ground) above trip point and switches off ( removes ground) when power is switched off. - Models TDX6-B and TDX6-D: Six ( 6) isolated Field-Effect Transistor ( F.E.T.) outputs; 0.1 A @ 250 VDC; switches on ( applies ground) above trip point and switches off ( removes ground) below trip point. * Operating Temperature: -4 to 158° F ( -20 to 70° C) . * Storage Temperature: -40 to 300° F ( -40 to 150° C) . * Case: ABS 1/ 4 DIN ( 90 x 90 mm) . * Scanning Speed: Complete scan in 30 seconds. * Reset Differential: F.E.T. models: Decreases 3 Degrees ( ° F or ° C) . S.C.R. models: Turn input power off to reset. * Display Update Time: Updates temperature every 0.3 seconds. * Start-up Time Delay: Unit is locked out for 10 seconds after ignition voltage is sensed. * Ambient Cold Junction Compensation Range: 2° F from 32° F to 122° F ( 1° C from 0° C to 50° C) . * Measurement Range: Monitor Range 0-1999° F or ° C ( specify ° F or ° C in part number) . * Accuracy: - With J-type thermocouple: from 50-150° F ( 10-66° C) + 3° F( + 2° C) , from 150-1200° F ( 66-649° C) ± 1.0% of reading. * With K-type thermocouple: from 400-2000° F ( 204-1076° C) ± 1.0% of reading. * Trip Point Accuracy: ± 3° F ( ± 2° C) of reading. * Trip Point Adjustment Range: 0-1999 Degrees. * Open Thermocouple Input: A number 1 appears in the display to the right of the channel number and the trip point operates.
Tampilkan Lebih Banyak